The 360 System extends the Ancon range to 56mm diameter. This system uses bar with minimum yield strength of 360N/mm² and is only available in carbon steel.

Ancon 360 System - Carbon Steel only
THREAD SIZE 48 56
Failure Loads (kN) 760 1055
Yield Loads (kN) 510 710
Design Capacities (kN) 608 844