Head Restraints
Ancon Head Restraints provide the necessary restraint to the top of masonry walls. They allow for vertical movement to accommodate shrinkage or thermal movement of the wall or structural frame, while restraining wind loads.
Ancon IHR – Internal Head Restraint
The Ancon IHR is used for restraining the top of internal walls or the top of the inner leaf of a cavity wall. The channel stem is closed at the front to prevent mortar ingress and to ensure that vertical movement can take place between the blockwork and the structure.
An IHR comprises a sliding top section and a stem. The standard length of an IHR sliding top section will accommodate a gap of up to 50mm. Longer top sections are available to accommodate gaps of up to 100mm, ideal when a fire stop is being incorporated at the wall head or where greater deflection is expected in the floor.
The standard Ancon IHR stem will suit a 215mm high block. IHR stems for taller block heights are available on request, however in such cases the stem may not be able to accommodate a gap above the block of more than 40mm.
The sliding tie can be provided with a hole (IHR-B) or slot (IHR-V) to suit M8 bolts, with a notch end to fix directly into a 38/17 or 30/20 cast-in channel (IHR-C), and with a notch end to suit the Hammer-On section that attaches to a steel flange without site drilling (IHR-H). It is also available to suit the SDTSS-38-5PT self-tapping screw (IHR-S).
Example IHR Specification
(Delete/Amend as appropriate)
Ancon IHR-B / IHR-V / IHR-S / IHR-C30 / IHR-C38 internal head restraint to suit a 215mm block and a 25-50 / 51-75 / 76-100mm gap.
Design Resistances for IHR Range
Design Resistances - Full Block (215mm) |
|||||
---|---|---|---|---|---|
Product Reference | Spacing | 25mm Gap | 50mm Gap | 75mm Gap |
100mm Gap |
IHR-B, IHR-V, IHR-C and IHR-S | 900mm | 1.78kN/m | 1.22kN/m | 1.06kN/m | 1.06kN/m |
450mm | 3.56kN/m | 2.44kN/m | 2.11kN/m | 2.11kN/m | |
IHR-H | 900mm | 0.57kN/m | 0.57kN/m | 0.53kN/m | 0.53kN/m |
450mm | 1.13kN/m | 1.13kN/m | 1.06kN/m | 1.06kN/m |
Design Resistances - Cut Blocks (min. 140mm) |
|||||
---|---|---|---|---|---|
Product Reference | Spacing | 25mm Gap | 50mm Gap | 75mm Gap | 100mm Gap |
IHR-B, IHR-V, IHR-C and IHR-S | 900mm | 1.39kN/m | 0.96kN/m | 0.83kN/m | 0.83kN/m |
450mm | 2.79kN/m | 1.92kN/m | 1.66kN/m | 1.66kN/m | |
IHR-H | 900mm | 0.44kN/m | 0.44kN/m | 0.42kN/m | 0.42kN/m |
450mm | 0.89kN/m | 0.89kN/m | 0.84kN/m | 0.84kN/m |
Ancon FHR – Head Restraint
The Ancon FHR Head Restraint is used for restraining the top of internal walls or the internal leaf of a cavity wall. The two angles clamp the top of the wall and have 10mm diameter holes to suit M8 bolts. They are supplied with two holes in the longer angle to allow the restraint to fit 100mm and 140mm blockwork. Each restraint provides a design resistance of 1890N. If the FHR overhangs the structure, please contact Leviat's Technical Team.
Building Information Modelling
For BIM Objects of these products, please click here or visit NBS Source.
Latest News
Leviat's Innovation Shines in Shortlisted Projects at Brick Awards
World-leading engineered connections specialist, Leviat, has made a significant impact on the architectural landscape with its innovative solutions playing a key part in the success of nine shortlisted projects at the 48th Annual Brick Awards, the longest and most widely respected design and construction awards in the UK.